![]() ![]() ![]() Find more information on the Primary Control Loop and other individual loops running on the NI VeriStand Engine in NI VeriStand Engine Architecture.Įxpand Controller in the tree and note the various items you can add to your System Definition. The Primary Control Loop controls the timing for the NI VeriStand Engine and keeps updated channel values. While in the Controller section, the setting for Target Rate underneath the Timing Source Settings section sets the Primary Control Loop rate on your target. Configuring the NI VeriStand Engine Using the System Explorer Rename the controller Name to a unique name of your choosing. Note localhost is the automatic selection for IP address, which indicates that the System Definition runs on the host PC. Running the NI VeriStand Engine on the Localhost Windows ComputerĬonfigure the Windows target by highlighting Controller in the tree and selecting Windows for the OS. Note: The cRIO 904x controller is currently not supported in NI VeriStand. The choices for VeriStand will match the Real-Time Controllers and RTOS Compatibility documentation. Note: The Operating System drop down has the choice for Phar Lap*, VxWorks, Linux_32_ARM, and Linux_圆4 as of VeriStand 2014. Rename the controller Name to a unique name of your choosing.Ĭonfigure the CompactRIO target by highlighting Controller in the tree, selecting VxWorks for the OS, and using the same IP address displayed for the CompactRIO system in MAX. For more information, please see the Phar Lap RT OS EOL Road Map.Ĭonfigure the PXI target by highlighting Controller in the tree, selecting Phar Lap* for the OS, and using the same IP address displayed for the PXI system in MAX. Note: NI will remove support for Phar Lap for cRIO in the NI 2020 Software Release and for PXI in the NI 2022 Software Release. In the NI VeriStand Project Explorer window, expand the System Definition File tree item and open the *.nivssdf file found there by right-clicking on the file and selecting Launch System Explorer. This includes items such as Workspace files (.nivsscren), System Definition files (.nivssdf), Stimulus Profile files (.nivsstimprof), Real-Time sequence files (.nivsseq), models, and FPGA bitfiles or configuration files. Note: NI recommends keeping all project dependencies relative to the project file location and placing them in the same folder or in a subfolder. Open NI VeriStand ( Start»Programs» National Instruments»NI VeriStand) and create a New NI VeriStand Project. Choose your project name and directory path from the window that appears. You can see a list of currently installed software on your target by looking under the Remote Systems»Real-Time Target»Software item within the MAX tree structure as highlighted above. Optional: If you are using a CompactRIO device and you want to install the Scan Engine Custom device, select the NI-Industrial Communications for EtherCAT and I/O Variable Remote Configuration Web Service for installation as well.Ĭomplete the software installation process and reboot your real-time target. Optional: If you want to implement a distributed real-time test system that uses GE reflective memory interfaces, select the GE reflective memory software on the target for installation. This installs the NI VeriStand Engine as well as the software components required to run it. Select the Software item for your real-time target and choose Add/Remove Software.įor CompactRIO targets only: Select the Custom Software Installation option.Ĭhoose to install the NI VeriStand Engine. In Measurement & Automation Explorer, select your NI VeriStand real-time target under the Remote Systems tree item. Once you have all of the necessary software on your host computer, you need to install software on the real-time target computer by following the steps below. Software Installation on the Real-Time Target Optional: NI-Industrial Communications for EtherCAT (for CompactRIO Scan Engine and EtherCAT functionality)Īfter all installations are complete on the host PC, open NI Measurement & Automation Explorer to confirm the installed software by expanding the My System»Software item within the tree structure as shown below.Optional: NI-XNET (for CAN, LIN, or FlexRay functionality).Optional: NI-RIO (for CompactRIO or FPGA functionality).Once you have installed the NI VeriStand Model Framework, you can license it for free by using the NI VeriStand Model Generation Activation Utility found here.Īfter you install the necessary NI VeriStand software components, install NI Device Drivers from either the Device Drivers DVD or from NI Driver Downloads. For machines that do not need the NI VeriStand environment, select only the NI VeriStand Model Framework for installation. Note: The NI VeriStand Model Framework can be installed independently and licensed free of charge. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |